Main P/N
End Item
Title
Aero Info P/N
Applicability
Supersedes
Replaces
906-10246-3
Loop Resistance Tester
ALL

5900T4
Safety Barricade
777-ALL

A27038 -20 Breakout Box - Printed Circuit Card. Used to test printed circuit cards having common connectors.

Notes: Used with 160 pin connectors

27-MUL-1355
777-200A
777-200B
777-300


A32074 -1 Breakout Box - Relay System, Air/Ground. Used for continuity and voltage check of air ground relay system. (May use TE65B40719) 32-MUL-1367
777-200A
777-200B
777-300


A33003 -359 Breakout Box - Multipurpose. Used for component testing of panel assemblies. 33-MUL-1371
777-200A
777-200B
777-300
A33003-1
A33003-1
A33003-1

A38010 -11 Test Cable - Potable Water Quantity Xmtr. Used to provide electrical access to water tank quantity transmitter for calibration. 38-MUL-1583
777-200A
777-200B
777-300

A38010-1
A38010-1
A38010-1
B71034 -29 Test Equipment - Engine Pressure Monitoring. Used to monitor engine pressure during Test Procedure No. 9 PW4000 (767) Test Procedure No. 12 JT9D (767) 71-MUL-1395
777-200


B71034 -40 Test Equipment - Engine Pressure Monitoring. Used to monitor engine pressure during Test Procedure No. 9 PW4000 (767) Test Procedure No. 12 JT9D (767) 71-MUL-1395
777-200


B71034 -48 Test Equipment - Engine Pressure Monitoring. Used to monitor engine pressure during Test Procedure No. 9 PW4000 (767) Test Procedure No. 12 JT9D (767)

Notes: Has longer hoses required for use on the 767-300

71-MUL-1395
777-200

B71034-13
B71034 -63 Test Equipment - Engine Pressure Monitoring. Used to monitor engine pressure during Test Procedure No. 9 PW4000 (767) Test Procedure No. 12 JT9D (767)

Notes: Has longer hoses required for use on the 767-300

71-MUL-1395
777-200


C34005 -1 Extended Box - Radio Altimeter Receiver
Transmitter. Used in place of Radio Altimeter (RA) Receiver - Transmitter (RT) primarily AlliedSignal Model ALA-52B RA RT.

777-200A
777-200B
777-300


F70328 -1 Probe - Film Resistance Measuring. Used with multimeter to measure resistance of electrical bond between conductive coating on non-conductive plastic sheet and the grounding fasteners. 70-MUL-1601
777-200A
777-200B
777-300


J22004 -1 Test Eqpt - Autothrottle Gearbox, Brake. Used in the run-in and Acceptance Test Procedures for Autothrottle Brake (254W4101), Rudder Control Brake (253W3349), and Autothrottle Gearbox Brake (254W140) Assemblies. The J22004-1, -54 are for 50 Hz Power Systems and the J22004-2, -55 are for 60 Hz. 23-MUL-1344
777-200A
777-200B
777-300


J22004 -2 Test Eqpt - Autothrottle Gearbox, Brake. Used in the run-in and Acceptance Test Procedures for Autothrottle Brake (254W4101), Rudder Control Brake (253W3349), and Autothrottle Gearbox Brake (254W140) Assemblies. The J22004-1, -54 are for 50 Hz Power Systems and the J22004-2, -55 are for 60 Hz.
777-200A
777-200B
777-300


J22004 -2 Test Eqpt - Autothrottle Gearbox, Brake. Used in the run-in and Acceptance Test Procedures for Autothrottle Brake (254W4101), Rudder Control Brake (253W3349), and Autothrottle Gearbox Brake (254W140) Assemblies. The J22004-1, -54 are for 50 Hz Power Systems and the J22004-2, -55 are for 60 Hz.
777-200A
777-200B
777-300


J22004 -54 Test Eqpt - Autothrottle Gearbox, Brake. Used in the run-in and Acceptance Test Procedures for Autothrottle Brake (254W4101), Rudder Control Brake (253W3349), and Autothrottle Gearbox Brake (254W140) Assemblies. The J22004-1, -54 are for 50 Hz Power Systems and the J22004-2, -55 are for 60 Hz.
777-200A
777-200B
777-300


J22004 -55 Test Eqpt - Autothrottle Gearbox, Brake. Used in the run-in and Acceptance Test Procedures for Autothrottle Brake (254W4101), Rudder Control Brake (253W3349), and Autothrottle Gearbox Brake (254W140) Assemblies. The J22004-1, -54 are for 50 Hz Power Systems and the J22004-2, -55 are for 60 Hz.
777-200A
777-200B
777-300


J22004 -23 Test Eqpt - Cargo Stop/Lock Assemblies.
Functionally test the 451W1330, 451W1360, 451W460, 451W14470 Cargo Lock Assemblies.

777-200A
777-200B
777-300


J26002 -1 Used to monitor and troubleshoot the airplane wiring and cardfile backplane integrity by providing pin access to connectors. The -1 consists of a -4 extender card assembly and a -7 storage box assy.
777-200A
777-200B
777-300


J26002 -2 Used to monitor and troubleshoot the airplane wiring and cardfile backplane integrity by providing pin access to connectors. The -2 consists of a -5 extender card assembly and a -8 storage box assy.

Notes: The -2 is used on MT&D/MBC cardfile (P29) (located in the back of the closet in the flight deck).


777-200A
777-200B
777-300


J26002 -3 Used to monitor and troubleshoot the airplane wiring and cardfile backplane integrity by providing pin access to connectors. The -3 consists of a -6 extender card assembly and a -9 storage box assy.

Notes: The -3 is used on the overhead panel card files (2) (located in the P61 panel area of the flight deck).


777-200A
777-200B
777-300


J26003 -12 Test Box - Time Delay, Cargo Fire Extinguishing Bottle. Used to record the elapsed time between the initial and secondary squib firings of the cargo fire extinguishing bottles.

Notes: Used with J26004 Squib Test Box.

26-B77-1584
777-200A
777-200B
777-300


J26004 -24 Test Equipment - Squib, Fire Extinguishing
System. Used to verify the required voltage at the appropriate squib connector upon discharge.
26-B77-1585
777-200A
777-200B
777-300
J26004-2
J26004-2
J26004-2

J26004 -25 Test Equipment - Squib, Fire Extinguishing
System. Used to verify the required voltage at the appropriate squib connector upon discharge.
26-B77-1585
777-200A
777-200B
777-300
J26004-3
J26004-3
J26004-3

J26004 -26 Test Equipment - Squib, Fire Extinguishing
System. Used to verify the required voltage at the appropriate squib connector upon discharge.
26-B77-1585
777-200A
777-200B
777-300
J26004-4
J26004-4
J26004-4

J26004 -27 Test Equipment - Squib, Fire Extinguishing
System. Used to verify the required voltage at the appropriate squib connector upon discharge.
26-B77-1585
777-200A
777-200B
777-300
J26004-5
J26004-5
J26004-5

J26004 -28 Storage Box, Test Equipment - Squib, Fire
Extinguishing System.
26-B77-1585
777-200A
777-200B
777-300
J26004-5
J26004-5
J26004-5

J26004 -43 Cable Assy - Squib, Fire Extinguishing System. Used to verify the required voltage at the appropriate squib connector upon discharge. 26-B77-1585
777-200A
777-200B
777-300
J26004-5
J26004-5
J26004-5

J26006 -1 Controller - Power Supply, E/E Cooling Fans.Used for facilitating the operation of the Electrical/Electronic Cooling Fans (Vent and Left Supply Fan) during a normal disabler test. Consists of -2 controller assy and -3 storage box.
777-200A
777-200B
777-300


J26007 -1 Test Box, Cargo Smoke Heater Test Plug. Used to simulate Heater Sensor Circuit and measure voltage output of the Cargo Smoke Detection System Heater Controllers. (Applicable to 777-200; 767 GMF; 747-400 All except freighters).
777-200A
777-200B


J27056 -1 Test Eqpt - Run In, Variable Drive. Used in conjunction with customer furnished component test fixtures to accomplish run-in tests.
777-200A
777-200B
777-300



J27056 -2 Test Eqpt - Run In, Variable Drive. Used in conjunction with customer furnished component test fixtures to accomplish run-in tests.
777-200A
777-200B
777-300



J27056 -38 Test Eqpt - Run In, Variable Drive. Used in conjunction with customer furnished component test fixtures to accomplish run-in tests.
777-200A
777-200B
777-300



J27056 -39 Test Eqpt - Run In, Variable Drive. Used in conjunction with customer furnished component test fixtures to accomplish run-in tests.
777-200A
777-200B
777-300


J32001 -46 Measuring Equipment - Brake Pedal. Used to measure the load applied and the angle of travel of the brake pedals. 32-MUL-1539
777-200A
777-200B
777-300

J32001-43
J32001-43
J32001-43
J34001 -17 Breakout Box - Line Maintenance. Used to provide pin access for LRU rack connectors. 34-B77-1586
777-200A
777-200B
777-300


J34001 -18 Breakout Box - Line Maintenance. Used to provide pin access for LRU rack connectors. 34-B77-1586
777-200A
777-200B
777-300


J34001 -19 Breakout Box - Line Maintenance. Used to provide pin access for LRU rack connectors. 34-B77-1586
777-200A
777-200B
777-300


J34001 -20 Breakout Box - Line Maintenance. Used to provide pin access for LRU rack connectors. 34-B77-1586
777-200A
777-200B
777-300



J34001 -23 Breakout Box - Line Maintenance. Used to provide pin access for LRU rack connectors. 34-B77-1586
777-200A
777-200B
777-300


J34001 -24 Breakout Box - Line Maintenance. Used to provide pin access for LRU rack connectors. 34-B77-1586
777-200A
777-200B
777-300



J34001 -25 Breakout Box - Line Maintenance. Used to provide pin access for LRU rack connectors. 34-B77-1586
777-200A
777-200B
777-300


J34001 -26 Breakout Box - Line Maintenance. Used to provide pin access for LRU rack connectors. 34-B77-1586
777-200A
777-200B
777-300


J34001 -27 Breakout Box - Line Maintenance. Used to provide pin access for LRU rack connectors. 34-B77-1586
777-200A
777-200B
777-300


J34001 -28 Breakout Box - Line Maintenance. Used to provide pin access for LRU rack connectors. 34-B77-1586
777-200A
777-200B
777-300


J34001 -50 Breakout Box - Line Maintenance. Used to provide pin access for LRU rack connectors. 34-B77-1586
777-200A
777-200B
777-300


J34001-19
J34001-19
J34001-19
J34001 -51 Breakout Box - Line Maintenance. Used to provide pin access for LRU rack connectors. 34-B77-1586
777-200A
777-200B
777-300


J34001-20
J34001-20
J34001-20
J34001 -52 Breakout Box - Line Maintenance. Used to provide pin access for LRU rack connectors.. 34-B77-1586
777-200A
777-200B
777-300

J34001-23
J34001-23
J34001-23
J34001 -53 Breakout Box - Line Maintenance. Used to provide pin access for LRU rack connectors. 34-B77-1586
777-200A
777-200B
777-300

J34001-24
J34001-24
J34001-24
J34001 -54 Breakout Box - Line Maintenance. Used to provide pin access for LRU rack connectors. 34-B77-1586
777-200A
777-200B
777-300

J34001-25
J34001-25
J34001-25
J34001 -55 Breakout Box - Line Maintenance. Used to provide pin access for LRU rack connectors. 34-B77-1586
777-200A
777-200B
777-300


J34001-26
J34001-26
J34001-26
J34001 -56 Breakout Box - Line Maintenance. Used to provide pin access for LRU rack connectors. 34-B77-1586
777-200A
777-200B
777-300

J34001-27
J34001-27
J34001-27
J34001 -57 Breakout Box - Line Maintenance. Used to provide pin access for LRU rack connectors. 34-B77-1586
777-200A
777-200B
777-300

J34001-28
J34001-28
J34001-28
J34001 -58 Breakout Box - Line Maintenance. Used to provide pin access for LRU rack connectors. 34-B77-1586
777-200A
777-200B
777-300


J34001-17
J34001-17
J34001-17
J34001 -59 Breakout Box - Line Maintenance. Used to provide pin access for LRU rack connectors. 34-B77-1586 777-200A
777-200B
777-300

J34001-18
J34001-18
J34001-18
J52027 -1 Test Box - Connector, Squib. Used to aid in measuring continuity and battery pack voltage at the EPAS Reservoir Squib Connector (DM52109).
777-200A
777-200B
777-300


J52029 -1 Test Eqpt - Squib, Overwing Exit. Used to verify Squib firing current on Escape Slide, EPAS (Emergency Power Assist System).
777-300